医疗系统用发电机组Hospital generator

Hospital generator
It boasts exceptional reliability, stability, and safety, capable of automatically starting immediately or within a short time when the mains power is interrupted, providing uninterrupted power supply for life-sustaining and critical medical equipment.
Chinese manufacturer of hospital generators
Hospital generator, a Chinese manufacturer of hospital generators, is on standby 24/7. Its core mission is to provide reliable, stable, and uninterrupted power supply immediately and automatically in case of municipal power grid failure, power outage, or other emergency situations, ensuring that critical medical activities are not interrupted.
The generator used in hospitals is a crucial backup power equipment in hospitals, clinics, and other medical facilities. It is the heart of the emergency power supply system in medical facilities and directly affects the safety of patients' lives.
-
Application Scenarios of Hospital Generators
The electrical load of medical facilities is classified into different levels, which can be categorized by application scenarios as follows:
Life Safety Branch: Operating Rooms, Intensive Care Units, Emergency Rooms, Delivery Rooms, and Neonatal Intensive Care Units.
Key branches: medical gas systems, lighting in critical areas, fire alarm and sprinkler systems, data centers, and hospital information systems.
Equipment Branches: Large medical equipment, blood banks, pharmaceutical refrigerators, and autoclaves in disinfection supply centers, etc.
-
Core components of hospital generators
Generator set: the power core.
Automatic Transfer Switch (ATS): The "brain" of the system, responsible for monitoring the mains power and automatically switching between sources.
Uninterruptible Power Supply (UPS): A bridge that provides "zero-second switching" for operating rooms, ICUs, and other critical areas.
Power distribution system: dedicated emergency power supply lines.
Monitoring System: It can monitor the mains power in real time and immediately send a start signal to the generator in case of a malfunction.
Noise Control: Equipped with high-efficiency mufflers and soundproof enclosures to ensure compliance with environmental regulations and minimize disturbance to patients and surrounding communities.
Hospital Generator Knowledge Q&A
1、 How to choose and configure generators for hospitals?
Accurately calculate the total power of all critical loads by professional engineers, taking into account the start-up surge current of large equipment such as MRI, leaving sufficient margin (usually 1.5 times or more).
2、What are the commonly used fuel types for hospital generators?
Diesel: the most commonly used, with high power, stable and safe fuel, and easy storage.
Natural gas: clean and environmentally friendly, can be supplied through pipelines, and does not require large storage. But relying on the municipal pipeline network may cause interruptions in disasters such as earthquakes.
Dual fuel: Combining the advantages of diesel and natural gas, it has higher reliability.
3、What are the cooling methods for hospital generators?
Liquid cooling: Low noise, stable performance, suitable for high-power and long-term operation scenarios.
Air cooling: With a simple structure and low cost, but high noise and relatively low power, it is commonly used in small clinics or non core areas.